Guide · HVAC

Duct bids and cooling projects: a bidding playbook

Sheet metal and cooling bids are won on clear scope, credible fabrication and installation pricing, and complete equipment quotes. This playbook organizes the bid from invitation to follow-up, with the duct weight math and the code items that change price.

  • Scope review
  • Fabrication and install
  • Equipment and cooling
  • Qualifications
Exposed spiral ductwork running through an open-ceiling commercial office

The playbook

StepWhat to settle
Scope reviewWho provides equipment, controls, insulation, TAB, rigging, fire stopping, coordination drawings
TakeoffDuct by system, size and pressure class; fittings; devices; accessories
FabricationWeight by gauge, shop hours, spiral versus rectangular, liner
InstallationField hours by size, height, access and congestion
Equipment and coolingQuotes for units, CRAH/CRAC, chillers, where in scope
SchedulePhasing, shifts, access, hoisting
QualificationsExclusions and assumptions
Follow-upClarify scope with the GC after bid day

Construction standard and pressure class first

Specs usually reference SMACNA's HVAC Duct Construction Standards: Metal and Flexible (4th edition, 2020, ANSI/SMACNA 006). Gauge, reinforcement, joints and seams depend on duct size and pressure class (for example 1/2, 1, 2, 3, 4, 6 or 10 in. w.g.). Mark pressure class on every system before taking off, because a 3 in. supply main and a 1/2 in. return of the same size are different weights and labor.

Duct by weight

A common basis for duct pricing is weight. Measure each run by size, convert to sheet metal area (perimeter times length), and multiply by the weight per square foot for the gauge.

Galvanized gaugeApprox. lb per sq ft
260.906
241.156
221.406
201.656
182.156
162.656
Illustrative weight calculation
duct = 24 x 14 rectangular, 120 ft, 22 ga assumed perimeter = 2 x (24 + 14) = 76 in. = 6.33 ft area = 6.33 x 120 = 760 sq ft weight = 760 x 1.406 ≈ 1,069 lb + seams, joints, reinforcement and hangers per your shop allowance

Gauge and allowances depend on the specified standard, pressure class and your shop practice. Round duct and spiral are usually priced by length and diameter from fabricator or supplier pricing rather than weight.

Leakage testing and sealing

Energy codes require leakage testing on higher-pressure ductwork. For example, the commercial provisions based on the 2024 IECC require ducts designed for 3 in. w.g. or more to be leak tested per the SMACNA HVAC Air Duct Leakage Test Manual to a leakage class of 4.0 or less, with representative sections totaling at least 25% of duct area. Specs often add more. Price test equipment, crew time, retests and documentation, and the sealing the test implies.

Fabrication and installation are different businesses

Price shop and field separately so you can see where margin is. Shop hours follow weight, fitting count and complexity; field hours follow size, height, access, congestion and coordination. Duct hung high in open structure, gyms or atriums needs lifts and moves slower than duct in a standard ceiling; work over occupied or finished areas needs protection. Note the access method in the proposal.

Cooling projects

Data centers and industrial cooling add large equipment, chilled water or refrigerant piping, redundancy (N+1, 2N), containment and commissioning. Duct may be a smaller share than equipment and piping. Read the basis of design and commissioning levels carefully.

ItemNote
Cooling unitsQuote with options, redundancy and startup
PipingSize, material, insulation, testing
DuctworkSupply and return, plenums, containment
ControlsOften separate
CommissioningLevels and witness testing

Qualifications for duct bids

  • Duct construction standard and pressure classes assumed.
  • Sealing and leakage testing included or excluded, per spec and energy code.
  • Insulation and liner by whom.
  • Access doors, dampers and accessories included as scheduled (see the damper takeoff guide).
  • Seismic bracing included or by others, and on what basis.
  • Controls wiring excluded unless stated.
  • TAB by owner's agent or in scope (NEBB or AABC certified, if specified).
  • Hoisting, lifts and work hours assumed.
  • Coordination drawings or BIM included, and to what level.

Comparing duct bids

GCs and mechanical contractors who subcontract sheet metal compare by scope as well as price. A level sheet lists each system, accessories, insulation, testing, coordination drawings, hoisting and exclusions for every bidder. A bid that looks low often omits accessories or testing; structure your proposal so it fits that comparison.

Bid day checks

  • Addenda checked for duct changes.
  • Insulation and accessory quotes confirmed.
  • Price per pound and hours per pound compared with similar jobs; an outlier points to a quantity or scope error.
When weight pricing does not fit: small residential and light commercial work with flex and spiral is often priced per system or per outlet. Use the method your history supports.

Where RenderDraw fits

RenderDraw's AI takeoff proposes duct runs and equipment counts from mechanical drawings with sources for estimator review. Try a free sample takeoff, or see the mechanical estimating guide.

Where RenderDraw fits

Equipment counts and duct runs, checked before pricing.

RenderDraw reads mechanical plans with schedules and specs, proposes equipment counts, duct and pipe runs with the source attached, and puts uncertain items in front of your estimator first.

  • Equipment from schedules and plans. Traceable to the source sheet.
  • Duct and pipe runs. Proposed lengths your estimator accepts or corrects.
  • Addenda through the same review. Send the changed sheets back through takeoff and estimator review.
  • Your labor and pricing. Applied to reviewed rows only.
Galvanized sheet metal HVAC duct fittings and a diffuser laid out for a ductwork takeoff
Honest by design

Send one mechanical set

Files stay private while RenderDraw assesses the request. No obligation.

RenderDraw does not publish accuracy percentages or time-saved claims. Test it on your own plan set.

FAQ

Questions estimators ask.

How is ductwork priced?

Commonly by weight: perimeter times length gives sheet area, times the weight per square foot for the gauge, plus allowances. Shop and field labor are priced separately.

How much does galvanized sheet weigh per square foot?

Approximately 0.906 lb for 26 gauge, 1.156 for 24, 1.406 for 22, 1.656 for 20, 2.156 for 18 and 2.656 for 16.

Which duct standard do specs reference?

Usually SMACNA HVAC Duct Construction Standards: Metal and Flexible, 4th edition (2020).

When is duct leakage testing required?

Energy codes based on the IECC require testing of ducts designed for 3 in. w.g. or more, at least 25% of duct area, to leakage class 4.0 or less, per the SMACNA test manual. Specs may require more.

What should duct bid qualifications cover?

Construction standard and pressure classes, sealing and testing, insulation, accessories, seismic, controls, TAB, hoisting, work hours and coordination drawings.

Start small

Duct runs and equipment from the drawings.

RenderDraw proposes duct runs and equipment counts with sources.

  1. Upload the plans, specs and schedules, plus an addendum if you have one.
  2. RenderDraw reviews the set and the scope you want tested.
  3. We follow up with extracted quantities, flagged items and next steps.
Sources

Sources and further reading

Standards, manufacturer data and references used for this guide. Numbers marked as rules of thumb are starting points, not substitutes for your own cost history, the project specifications or the manufacturer's current data.

  1. SMACNA: HVAC Duct Construction Standards, Metal and Flexible, 4th edition — Construction standard
  2. SMACNA technical standards — Leakage test manual and related standards
  3. UpCodes: C403.13.2.3 High-pressure duct systems (2024 IECC-based) — 3 in. w.g., CL 4.0, 25% tested
  4. NEBB — TAB certification
  5. AABC — TAB certification

Last reviewed November 2026.